Click or drag to resize

wclObexServerClientPutCompletedEvent Delegate

The OBEX server data processor OnPutCompleted event handler prototype.

Namespace: wclCommunication
Assembly: wclCommunication (in wclCommunication.dll) Version: 7.9.6.0 (7.9.6.0)
Syntax
public delegate void wclObexServerClientPutCompletedEvent(
	Object Sender,
	int Error,
	Stream Stream,
	out bool Accept
)

Parameters

Sender  Object
The object that initiated the event.
Error  Int32
The operation completion reason code. If operation completed with success the Reason is WCL_E_SUCCESS. An application may accept or reject all the object by setting the Accept parameter.
Stream  Stream
The received object's data stream.
Accept  Boolean
Set this parameter to True to accept the object. Set this parameter to False to reject the object. In case if object rejected the OBEX Forbidden error will be send.
Remarks
The Stream parameter contains the received object's data. This parameter is valid only inside the event handler and must be saved or copied by an application if an application needs to use it later. The Stream parameter can be null or empty if received object does not have body (data).
See Also